NCT03109262 · REGISTRY CONDITION SEARCH
Yttrium-90 (Y90) Glass Microspheres PET/CT in Imaging Patients With Liver Tumors
Found through the registry condition index, not selected as a treatment recommendation. This discovery collection was restricted to studies with posted results.
- Phase
- NA
- Status at capture
- COMPLETED
- Registry last update
- 2022-01-10
This clinical trial studies how well yttrium-90 (Y90) glass microspheres positron emission tomography (PET)/computed tomography (CT) works in imaging patients with liver tumors . Images produced by PET/CT may provide better information about the distribution of particles, such as Y90 glass microspheres, delivered for selective internal radiation therapy (SIRT) as compared to regular medical care images useing technetium Tc-99m albumin-aggregated single photon emission computed tomography (SPECT)/CT images.
Open the original ClinicalTrials.gov record → · Download preserved record
What did the study report?
Outcomes, safety and baseline populations are separate source sections. Quality-of-life measures appear under their original outcome titles.
Who could take part
- eligibility Criteria
- Inclusion Criteria: * Patient provides written informed consent * Patient is referred for 90Y SIRT radioembolization of liver tumor(s) * Patient is capable of complying with study procedures * Patient is able to remain still for duration of imaging procedure (approximately 30 minutes total for digital PET/CT) Exclusion Criteria: * Patient is pregnant or nursing
- healthy Volunteers
- false
- minimum Age
- 18 Years
- sex
- ALL
- std Ages
- ADULT
- OLDER_ADULT
Treatment arms and interventions
- arm Groups
- description
- All participants receive both Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- intervention Names
- Procedure: Computed Tomography (CT)
- Procedure: Positron Emission Tomography (PET)
- Device: 90-Yttrium (Y-90) Glass Microspheres
- Diagnostic Test: Technetium 99mTc albumin aggregated (99mTc-MAA)
- Procedure: Single-photon emission computerized tomography (SPECT) scan
- label
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- type
- EXPERIMENTAL
- interventions
- arm Group Labels
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- description
- As part of PET/CT and SPECT/CT scans.
- name
- Computed Tomography (CT)
- other Names
- CAT
- CAT Scan
- Computed Tomography
- Computerized Axial Tomography
- Computerized Tomography
- CT
- CT SCAN
- tomography
- X-ray
- type
- PROCEDURE
- arm Group Labels
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- description
- As part of PET/CT scan
- name
- Positron Emission Tomography (PET)
- other Names
- Medical Imaging, Positron Emission Tomography
- PET
- PET SCAN
- Positron Emission Tomography
- Positron Emission Tomography Scan
- Positron-Emission Tomography
- proton magnetic resonance spectroscopic imaging
- type
- PROCEDURE
- arm Group Labels
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- description
- Radiolabel for PET/CT scan
- name
- 90-Yttrium (Y-90) Glass Microspheres
- other Names
- TheraSphere
- type
- DEVICE
- arm Group Labels
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- description
- Radiolabel for 99mTc-MAA SPECT/CT Scan
- name
- Technetium 99mTc albumin aggregated (99mTc-MAA)
- other Names
- 99mTc-MAA
- type
- DIAGNOSTIC_TEST
- arm Group Labels
- Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
- description
- As part of SPECT/CT scan
- name
- Single-photon emission computerized tomography (SPECT) scan
- other Names
- SPECT Scan
- type
- PROCEDURE
Study design
- allocation
- NA
- intervention Model
- SINGLE_GROUP
- masking Info
- masking
- NONE
- primary Purpose
- DIAGNOSTIC
Enrollment
- count
- 42
- type
- ACTUAL
Registered outcome plans (not posted results)
- primary Outcomes
- description
- Image quality for 90Y PET/CT scan images was assessed relative to the expected image quality of Standard of Care (SoC) 99mTc-MAA SPECT/CT scans obtained from the same participant. Assessments were conducted at 5, 10, 15 and 20 minutes after infusion. Scans were assessed on a 1 to 5 Likert scale by 2 Nuclear Medicine physicians who were blinded to patient information. The Likert scale for image quality was established as follows: 1. = Non-diagnostic 2. = Suboptimal 3. = Acceptable 4. = Good 5. = Excellent, equivalent to a SoC 99mTc-MAA SPECT/CT scan The scans for each individual participant at each timepoint was scored on the Likert scale, as determined by the 2 Nuclear Medicine physicians. The outcome is reported as the overall mean of the physician determinations for each time point, with standard deviation.
- measure
- Image Quality for 90-Y PET/CT Scans
- time Frame
- 1 day
- secondary Outcomes
- description
- Radiopharmaceutical dosimetry was assessed based on the numerical tumor-absorbed dose value in Gray as calculated by SurePlan (MIM Software Inc, Cleveland, Ohio). The outcome is reported as the median tumor-absorbed dose in Gray for each scan method (90Y PET/CT and 99mTc-MAA SPECT/CT), with standard deviation.
- measure
- Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans
- time Frame
- 1 day
Full study description
- brief Summary
- This clinical trial studies how well yttrium-90 (Y90) glass microspheres positron emission tomography (PET)/computed tomography (CT) works in imaging patients with liver tumors . Images produced by PET/CT may provide better information about the distribution of particles, such as Y90 glass microspheres, delivered for selective internal radiation therapy (SIRT) as compared to regular medical care images useing technetium Tc-99m albumin-aggregated single photon emission computed tomography (SPECT)/CT images.
- detailed Description
- PRIMARY OBJECTIVES: I. To evaluate the image quality of yttrium-90 (Y90) microspheres PET/CT post SIRT images as compared to technetium Tc-99m albumin aggregated (99mTc MAA) SPECT/CT. SECONDARY OBJECTIVES: I. To determine the superior accuracy in both distribution and dosimetry of Y90 PET/CT post-SIRT imaging compared to 99mTc MAA planar and SPECT/CT imaging. OUTLINE: Immediately after standard of care SIRT, patients receive Y90 glass microspheres and undergo PET/CT over 30 minutes. This study compares the experimental images to the regular medical care images in the same participant.
Source references
- references
- citation
- Duan H, Khalaf MH, Ferri V, Baratto L, Srinivas SM, Sze DY, Iagaru A. High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner. Eur J Nucl Med Mol Imaging. 2021 Jul;48(8):2426-2436. doi: 10.1007/s00259-021-05188-4. Epub 2021 Jan 14.
- pmid
- 33443618
- type
- RESULT
Source notices and limitations
Discovery and provenance
- release id
- ctgov-registry-1336d216cbd1bbff780dac70
- edge id
- nct-edge-81062c9e9ed351decd43
- requested nct id
- NCT03109262
- primary nct id
- NCT03109262
- source kind
- ctgov_condition_query
- source record id
- Source null
- source file sha256
- 9d7960d89169a453f1ac7b2a50046538e920fc46c1e81576f7eac42f88243453
- payload sha256
- fafa44676c1e86b5877d8348a302f63703a2c95b2c8fe104cb58545068e3de1c
- payload
- clinical indication matching status
- condition_index_match_asserted_by_registry_not_reviewed
- end exclusive
- true
- id
- nct-edge-81062c9e9ed351decd43
- link basis
- returned_by_explicit_condition_and_posted_results_filter_query
- nct id
- NCT03109262
- occurrences
- context exact
- NCT03109262
- end
- 11
- exact text
- NCT03109262
- start
- 0
- offset unit
- unicode_code_points
- query cond
- Childhood Liver Cancer
- query disease state id
- ds-liver-cancer-pediatric
- source file
- /Users/arunverma/Documents/ChatGPT/Cancer Statistics Website/research-data/2026-09-10/clinicaltrials-condition/round-0000/raw/cond-childhood-liver-cancer-000.json
- source file sha256
- 9d7960d89169a453f1ac7b2a50046538e920fc46c1e81576f7eac42f88243453
- source json pointer
- /studies/1/protocolSection/identificationModule/nctId
- source kind
- ctgov_condition_query
- source record id
- Source null
- source string basis
- parsed_JSON_string_unmodified
- source string sha256
- 81e741d6d0c56e53ea854b06d6c220f1ac490ee21c265231b61f08843ac63ceb
Preserved source evidence · Not medical advice
Triangle