NCT03109262 · OUTCOME
Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans
Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.
- Measure
- MEDIAN
- Unit
- Gray
- Interval / dispersion
- Standard Error
- Time frame
- 1 day
What was measured
Radiopharmaceutical dosimetry was assessed based on the numerical tumor-absorbed dose value in Gray as calculated by SurePlan (MIM Software Inc, Cleveland, Ohio). The outcome is reported as the median tumor-absorbed dose in Gray for each scan method (90Y PET/CT and 99mTc-MAA SPECT/CT), with standard deviation.
Groups in this outcome
Yttrium Y-90 PET/CT
All participants receive Y-90 PET/CT Scan Computed Tomography (CT): As part of PET/CT scan. Positron Emission Tomography (PET): As part of PET/CT scan 90-Yttrium (Y-90) Glass Microspheres: Radiolabel for PET/CT scan
99mTc-MAA SPECT/CT Scans
All participants receive 99mTc-MAA SPECT/CT scan Computed Tomography (CT): As part of SPECT/CT scans. Single-photon emission computerized tomography (SPECT) scan: As part of SPECT/CT scan Technetium 99mTc albumin aggregated (99mTc-MAA): Radiolabel for 99mTc-MAA SPECT/CT Scan
| Group | Source count |
|---|---|
| Yttrium Y-90 PET/CT | 42 |
| 99mTc-MAA SPECT/CT Scans | 42 |
Reported measurements
Source class 1
| Group | Value | Spread | Lower | Upper | Comment |
|---|---|---|---|---|---|
| Yttrium Y-90 PET/CT | 142.9 | 99.7 | Not reported | Not reported | Not reported |
| 99mTc-MAA SPECT/CT Scans | 118.9 | 91.0 | Not reported | Not reported | Not reported |
Complete source fields
- classes
- categories
- measurements
- group Id
- OG000
- spread
- 99.7
- value
- 142.9
- group Id
- OG001
- spread
- 91.0
- value
- 118.9
- denoms
- counts
- group Id
- OG000
- value
- 42
- group Id
- OG001
- value
- 42
- units
- Participants
- description
- Radiopharmaceutical dosimetry was assessed based on the numerical tumor-absorbed dose value in Gray as calculated by SurePlan (MIM Software Inc, Cleveland, Ohio). The outcome is reported as the median tumor-absorbed dose in Gray for each scan method (90Y PET/CT and 99mTc-MAA SPECT/CT), with standard deviation.
- dispersion Type
- Standard Error
- groups
- description
- All participants receive Y-90 PET/CT Scan Computed Tomography (CT): As part of PET/CT scan. Positron Emission Tomography (PET): As part of PET/CT scan 90-Yttrium (Y-90) Glass Microspheres: Radiolabel for PET/CT scan
- id
- OG000
- title
- Yttrium Y-90 PET/CT
- description
- All participants receive 99mTc-MAA SPECT/CT scan Computed Tomography (CT): As part of SPECT/CT scans. Single-photon emission computerized tomography (SPECT) scan: As part of SPECT/CT scan Technetium 99mTc albumin aggregated (99mTc-MAA): Radiolabel for 99mTc-MAA SPECT/CT Scan
- id
- OG001
- title
- 99mTc-MAA SPECT/CT Scans
- param Type
- MEDIAN
- reporting Status
- POSTED
- time Frame
- 1 day
- title
- Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans
- type
- SECONDARY
- unit Of Measure
- Gray