Skip to content
← Full study record

NCT03078452 · OUTCOME

Bone Marrow Core Biopsy Length (in mm) and Artifacts Assessed by the Pathologist

Evaluating Effectiveness of Powered Drill Bone Marrow Biopsy · Source last updated 2025-09-08

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
MEAN
Unit
Millimeters
Interval / dispersion
95% Confidence Interval
Time frame
At the time of biopsy

What was measured

Bone marrow biopsy length is studied with mean, median, range, and standard deviation and compared by two-sample t-test.

Groups in this outcome

Arm I (Biopsy Using Power Drill)

Patients undergo bone marrow biopsy using the power drill. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7. Power drill: Undergo bone marrow biopsy using power drill

Arm II (Biopsy Using Jamshidi Needle)

Patients undergo bone marrow biopsy using the traditional Jamshidi needle. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7. Jamshidi needle: Undergo bone marrow biopsy using Jamshidi needle

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Arm I (Biopsy Using Power Drill)50
Arm II (Biopsy Using Jamshidi Needle)50

Reported measurements

Source class 1
Values in Millimeters · Interval/dispersion: 95% Confidence Interval
GroupValueSpreadLowerUpperComment
Arm I (Biopsy Using Power Drill)14Not reported530Not reported
Arm II (Biopsy Using Jamshidi Needle)9.5Not reported323Not reported
Complete source fields
classes
  1. categories
    1. measurements
      1. group Id
        OG000
        lower Limit
        5
        upper Limit
        30
        value
        14
      2. group Id
        OG001
        lower Limit
        3
        upper Limit
        23
        value
        9.5
denoms
  1. counts
    1. group Id
      OG000
      value
      50
    2. group Id
      OG001
      value
      50
    units
    Participants
description
Bone marrow biopsy length is studied with mean, median, range, and standard deviation and compared by two-sample t-test.
dispersion Type
95% Confidence Interval
groups
  1. description
    Patients undergo bone marrow biopsy using the power drill. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7. Power drill: Undergo bone marrow biopsy using power drill
    id
    OG000
    title
    Arm I (Biopsy Using Power Drill)
  2. description
    Patients undergo bone marrow biopsy using the traditional Jamshidi needle. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7. Jamshidi needle: Undergo bone marrow biopsy using Jamshidi needle
    id
    OG001
    title
    Arm II (Biopsy Using Jamshidi Needle)
param Type
MEAN
reporting Status
POSTED
time Frame
At the time of biopsy
title
Bone Marrow Core Biopsy Length (in mm) and Artifacts Assessed by the Pathologist
type
PRIMARY
unit Of Measure
Millimeters

Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f

Preserved source evidence · Not medical advice