NCT03078452 · REGISTRY CONDITION SEARCH
Evaluating Effectiveness of Powered Drill Bone Marrow Biopsy
Found through the registry condition index, not selected as a treatment recommendation. This discovery collection was restricted to studies with posted results.
- Phase
- NA
- Status at capture
- COMPLETED
- Registry last update
- 2025-09-08
Since the introduction of the Jamshidi needle in 1971, new advances in bone marrow sampling have not been seen. In 2007, a new battery-powered bone marrow biopsy system was developed. This technology, using a battery-powered drill to operate the needle accessing the posterior iliac bone, was approved by the Food and Drug Administration (FDA) and is currently commercially available. Few randomized controlled trials (RCTs) have compared the use of the battery-powered bone marrow biopsy system to the Jamshidi needle (the traditional manual) method of bone marrow sampling. This research study is designed to evaluate the effectiveness of the Jamshidi needle compared to the battery-powered bone marrow biopsy system. 100 participants will be enrolled in this study at Emory University.
Open the original ClinicalTrials.gov record → · Download preserved record
What did the study report?
Outcomes, safety and baseline populations are separate source sections. Quality-of-life measures appear under their original outcome titles.
Participant flow
Baseline characteristics
Bone Marrow Core Biopsy Length (in mm) and Artifacts Assessed by the Pathologist
Intensity of Pain Measured Using Visual Analogue Scale (VAS) Pain Questionnaire
Time Taken by the Procedure Measured in Seconds Using a Stopwatch
Adverse events
Limitations, agreements, and source contact
Who could take part
- eligibility Criteria
- Inclusion Criteria: * All patients with existing plasma cell disorders and no history of psychiatric disorders who can receive conscious sedation are eligible to participate in the trial Exclusion Criteria: * Pregnant women are excluded from participating in this study
- healthy Volunteers
- false
- sex
- ALL
- std Ages
- CHILD
- ADULT
- OLDER_ADULT
Treatment arms and interventions
- arm Groups
- description
- Patients undergo bone marrow biopsy using the power drill. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7.
- intervention Names
- Device: Power drill
- label
- Arm I (biopsy using power drill)
- type
- EXPERIMENTAL
- description
- Patients undergo bone marrow biopsy using the traditional Jamshidi needle. Patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7.
- intervention Names
- Device: Jamshidi needle
- label
- Arm II (biopsy using Jamshidi needle)
- type
- ACTIVE_COMPARATOR
- interventions
- arm Group Labels
- Arm I (biopsy using power drill)
- description
- Undergo bone marrow biopsy using power drill
- name
- Power drill
- type
- DEVICE
- arm Group Labels
- Arm II (biopsy using Jamshidi needle)
- description
- Undergo bone marrow biopsy using Jamshidi needle
- name
- Jamshidi needle
- type
- DEVICE
Study design
- allocation
- RANDOMIZED
- intervention Model
- PARALLEL
- masking Info
- masking
- NONE
- primary Purpose
- DIAGNOSTIC
Enrollment
- count
- 100
- type
- ACTUAL
Registered outcome plans (not posted results)
- primary Outcomes
- description
- Bone marrow biopsy length is studied with mean, median, range, and standard deviation and compared by two-sample t-test.
- measure
- Bone Marrow Core Biopsy Length (in mm) and Artifacts Assessed by the Pathologist
- time Frame
- At the time of biopsy
- secondary Outcomes
- description
- The VAS (visual analogue scale) for pain is on a 10 point scale. Pain is studied with chi-square, Mann Whitney U test, or Fisher's exact test. The pain scale used was 0-10, with 0 being no pain and 10 being the worst pain.
- measure
- Intensity of Pain Measured Using Visual Analogue Scale (VAS) Pain Questionnaire
- time Frame
- At the time of, 30 minutes, 1, 3, and 7 days after biopsy
- description
- Staff members will use a stopwatch from the beginning to the completion of the procedure (skin to skin). Time taken for procedure is studied with mean, median, range, and standard deviation and compared by two-sample t-test.
- measure
- Time Taken by the Procedure Measured in Seconds Using a Stopwatch
- time Frame
- At the time of biopsy
Full study description
- brief Summary
- Since the introduction of the Jamshidi needle in 1971, new advances in bone marrow sampling have not been seen. In 2007, a new battery-powered bone marrow biopsy system was developed. This technology, using a battery-powered drill to operate the needle accessing the posterior iliac bone, was approved by the Food and Drug Administration (FDA) and is currently commercially available. Few randomized controlled trials (RCTs) have compared the use of the battery-powered bone marrow biopsy system to the Jamshidi needle (the traditional manual) method of bone marrow sampling. This research study is designed to evaluate the effectiveness of the Jamshidi needle compared to the battery-powered bone marrow biopsy system. 100 participants will be enrolled in this study at Emory University.
- detailed Description
- PRIMARY OBJECTIVE: I. Assessing the quality and quantity of bone marrow core biopsies. SECONDARY OBJECTIVES: I. Assessing the nature of pain by established visual analogue scale (VAS) questionnaires. II. Timing of the actual procedure. OUTLINE: Patients are randomized to 1 of 2 arms. ARM I: Patients undergo bone marrow biopsy using the power drill. ARM II: Patients undergo bone marrow biopsy using the traditional Jamshidi needle. All patients complete questionnaires at baseline, 30 minutes after biopsy, and on days 1, 3, and 7. After completion of study treatment, patients are followed up periodically.
Source references
Source notices and limitations
Discovery and provenance
- release id
- ctgov-registry-1336d216cbd1bbff780dac70
- edge id
- nct-edge-228b7ae153a217c4e846
- requested nct id
- NCT03078452
- primary nct id
- NCT03078452
- source kind
- ctgov_condition_query
- source record id
- Source null
- source file sha256
- 2314ce01316b2d7044d298c6d25eda12e99cc5f44273bc75efed6cd5e03a8c14
- payload sha256
- e2cef2aad450de4ed036d0c414683826b70ffca52e957ea38daadadad2aa35ba
- payload
- clinical indication matching status
- condition_index_match_asserted_by_registry_not_reviewed
- end exclusive
- true
- id
- nct-edge-228b7ae153a217c4e846
- link basis
- returned_by_explicit_condition_and_posted_results_filter_query
- nct id
- NCT03078452
- occurrences
- context exact
- NCT03078452
- end
- 11
- exact text
- NCT03078452
- start
- 0
- offset unit
- unicode_code_points
- query cond
- Plasma Cell Neoplasms
- query disease state id
- ds-plasma-cell-neoplasms
- source file
- /Users/arunverma/Documents/ChatGPT/Cancer Statistics Website/research-data/2026-09-10/clinicaltrials-condition/round-0000/raw/cond-plasma-cell-neoplasms-000.json
- source file sha256
- 2314ce01316b2d7044d298c6d25eda12e99cc5f44273bc75efed6cd5e03a8c14
- source json pointer
- /studies/868/protocolSection/identificationModule/nctId
- source kind
- ctgov_condition_query
- source record id
- Source null
- source string basis
- parsed_JSON_string_unmodified
- source string sha256
- 925dd2cc80a9a14d4dc3ebb1cb242579542a9f8b5e91216b1b5b88c2f1115802
Preserved source evidence · Not medical advice
Triangle