Skip to content
← Study library

NCT05579782 · REGISTRY CONDITION SEARCH

Assessing Benefits of NIRAF Detection for Identifying Parathyroid Glands During Total Thyroidectomy

Found through the registry condition index, not selected as a treatment recommendation. This discovery collection was restricted to studies with posted results.

Phase
NA
Status at capture
COMPLETED
Registry last update
2025-07-31

This study describes a single center, randomized, single-blinded clinical trial to assess the clinical benefits of the use of near infrared autofluorescence (NIRAF) detection with an FDA-cleared device 'Parathyroid Eye (PTeye)' for identifying parathyroid glands during total thyroidectomy. It compares risk-benefits and outcomes in patients undergoing total thyroidectomy where NIRAF detection with PTeye for parathyroid identification is either used or not used.

Open the original ClinicalTrials.gov record → · Download preserved record

What did the study report?

Outcomes, safety and baseline populations are separate source sections. Quality-of-life measures appear under their original outcome titles.

Who could take part
eligibility Criteria
Inclusion Criteria: (i) All patients eligible for total thyroidectomy (TTx), with or without lymph node dissection. (includes patients undergoing a TTx who have undergone a prior neck exploration for parathyroid disease or other but have an intact thyroid). (ii) All patients undergoing completion thyroidectomy. Exclusion Criteria: (i) Patients with concurrent parathyroid disease. (ii) Patients with incidental enlarged parathyroid discovered during TTx. (iii) Patients undergoing thyroid lobectomy/partial thyroidectomy.
healthy Volunteers
true
maximum Age
99 Years
minimum Age
18 Years
sex
ALL
std Ages
  1. ADULT
  2. OLDER_ADULT
Treatment arms and interventions
arm Groups
  1. description
    Parathyroid gland identification will be performed with PTeye using NIRAF detection technology as an adjunctive tool in patients who undergo total thyroidectomy (TTx) with or without lymph node dissection (LND).
    intervention Names
    1. Device: NIRAF Detection Technology
    label
    NIRAF Detection Technology (+)
    type
    EXPERIMENTAL
  2. description
    Parathyroid gland identification will be performed by the surgeon using only visual identification and without using PTeye - NIRAF detection technology in patients who undergo total thyroidectomy (TTx) with or without lymph node dissection (LND).
    label
    NIRAF Detection Technology (-)
    type
    NO_INTERVENTION
interventions
  1. arm Group Labels
    1. NIRAF Detection Technology (+)
    description
    Near Infrared Autofluorescence (NIRAF) detection technology or 'PTeye' consists of a disposable fiber-optic probe that emits non-ionizing radiation from a NIR 785 nm laser source, and also transmits the resulting tissue NIRAF to a photo detector. The 785 nm laser source emits a maximum power of 20 mW. The device is FDA cleared for clinical use in general surgeries and dermatological use (Class 2 device). After surgeon identifies a potential parathyroid gland in the surgical field, the surgeon places the fiber-optic probe of PTeye on suspect tissue and presses the device foot-pedal to activate tissue NIRAF measurement. Auditory beep at high frequency with a Detection Ratio \> 1.2 is interpreted by device as the suspect tissue being positive for parathyroid. Other Name: PTeye Device
    name
    NIRAF Detection Technology
    type
    DEVICE
Study design
allocation
RANDOMIZED
intervention Model
PARALLEL
intervention Model Description
NIRAF detection technology is used as an adjunctive tool for intraoperative parathyroid identification in patients who undergo total thyroidectomy (TTx) with or without lymph node dissection (LND) in the interventional group. Generic Name of Device: Parathyroid Autofluorescence Detection Device (NIRAF detection technology). The Parathyroid Autofluorescence Detection Device consists of a disposable fiber-optic probe that emits non-ionizing radiation from a NIR 785 nanometer (nm) laser source, and also transmits the resulting tissue NIRAF to a photo detector. The 785 nm laser source emits a maximum power of 20 Milliwatts (mW). The device has an FDA clearance for clinical use in general surgeries and dermatological use (Class 2 device).
masking Info
masking
SINGLE
masking Description
Only participants will be masked to the intervention.
who Masked
  1. PARTICIPANT
primary Purpose
PREVENTION
Enrollment
count
80
type
ACTUAL
Registered outcome plans (not posted results)
primary Outcomes
  1. description
    The number of subjects with hypoparathyroidism. For the transient hypoparathyroidism; the definition utilized was a serum parathyroid hormone (PTH) level \<10 pg/mL.
    measure
    Subjects With Transient Hypoparathyroidism.
    time Frame
    24-48 hours post-op
  2. description
    The number of subjects with hypoparathyroidism at last follow-up. Follow-up defined as PTH less than the normal institutional range.
    measure
    Patients With Hypoparathyroidism at Last Follow-up
    time Frame
    2 days to 1 year after surgery
secondary Outcomes
  1. description
    Overall number of parathyroid glands identified (Experimental Group: Glands identified with naked eye + NIRAF; Control Group: Glands identified with naked eye)
    measure
    Overall Average Number of Parathyroid Glands Identified With High Confidence.
    time Frame
    Immediate (during total thyroidectomy, up to 3 hours)
  2. description
    Number of participants with frozen sections sent for analysis during the procedure to confirm potential parathyroid tissue.
    measure
    Number of Participants With Frozen Sections Sent for Analysis.
    time Frame
    Immediate (during total thyroidectomy, up to 3 hours)
  3. description
    Number of participants with auto-transplanted parathyroid glands if the parathyroid gland was accidentally excised/devascularized.
    measure
    Number of Participants With Auto-transplanted Parathyroid Glands
    time Frame
    Immediate (during total thyroidectomy, up to 3 hours)
  4. description
    Number of participants who spent nights for postoperative recovery in the hospital after the surgical procedure.
    measure
    Number of Participants Who Spent Nights in the Hospital After Total Thyroidectomy
    time Frame
    0-72 hours after total thyroidectomy
  5. description
    Number of participants with inadvertently resected parathyroid glands when parathyroid tissue is found in the resected thyroid specimens.
    measure
    Number of Participants With Inadvertently Resected Parathyroid Glands
    time Frame
    Immediate (intraoperative) to 7-10 days after total thyroidectomy (pathology report)
  6. description
    Number of doctor visits/emergency department visits or hospital admissions due to hypocalcemia and or associated symptoms.
    measure
    Number of Doctor Visits/Emergency Department Visits or Hospital Admissions
    time Frame
    Up to 6 months after total thyroidectomy
  7. description
    Duration and total daily dosage of calcium and/or vitamin D supplementation after surgery - if patient had no prior history of supplementation.
    measure
    Duration and Total Daily Dosage of Calcium and/or Vitamin D Supplementation After Surgery
    time Frame
    Up to 6 months after total thyroidectomy
Full study description
brief Summary
This study describes a single center, randomized, single-blinded clinical trial to assess the clinical benefits of the use of near infrared autofluorescence (NIRAF) detection with an FDA-cleared device 'Parathyroid Eye (PTeye)' for identifying parathyroid glands during total thyroidectomy. It compares risk-benefits and outcomes in patients undergoing total thyroidectomy where NIRAF detection with PTeye for parathyroid identification is either used or not used.
detailed Description
Inadvertent damage or excision of a healthy parathyroid gland (PG) following a total thyroidectomy (TTx) could result in transient hypocalcemia (\< 6 months) in 5 - 35% of cases or permanent hypocalcemia (\> 6 months) in 7% of the patients (1, 2). In both of these circumstances, patients would require calcium and active vitamin D supplementation in addition to a potentially prolonged hospital stay and/or unplanned hospital readmission adding to unnecessary burden and healthcare costs. These complications could be minimized with label-free intraoperative PG identification using near infrared autofluorescence (NIRAF) detection with a fiber-probe based approach as utilized in 'PTeye', which is medical device that was recently FDA-cleared. However, the true impact of this particular NIRAF-based approach on patient outcomes is yet to be determined The aim of this prospective single blinded randomized study is to compare 2 groups of patients: TTx patients operated using NIRAF detection technology with PTeye as adjunct tool (NIRAF+) vs. patients operated without the adjunct technology (NIRAF-). The main objective of this study is to assess the benefit of intraoperative use of NIRAF detection technology via PTeye during TTx procedures with regard to postoperative hypocalcemia, PG identification, PG auto-transplantation and inadvertent resection rates compared to standard of care.
Source references
references
  1. citation
    Cousart AG, Kiernan CM, Willmon PA, Thomas G, Wang TS, Gauger PG, Duh QY, Underwood HJ, Jackson A, Patel A, Mahadevan-Jansen A, Solorzano CC. Near-Infrared Autofluorescence for Parathyroid Detection During Endocrine Neck Surgery: A Randomized Clinical Trial. JAMA Surg. 2025 Sep 1;160(9):936-944. doi: 10.1001/jamasurg.2025.2233.
    pmid
    40668552
    type
    DERIVED
Source notices and limitations
    Discovery and provenance
    1. release id
      ctgov-registry-1336d216cbd1bbff780dac70
      edge id
      nct-edge-f7e571b9f9b8d654f2df
      requested nct id
      NCT05579782
      primary nct id
      NCT05579782
      source kind
      ctgov_condition_query
      source record id
      Source null
      source file sha256
      2b4988b513f0b70e7c49c0c10cabf5241c1231b8e29e89b78dc9406bd8749c8a
      payload sha256
      117517ff0687c1430475b8e293d92f08d27883b4807a64942dc6e4f40257d3e7
      payload
      clinical indication matching status
      condition_index_match_asserted_by_registry_not_reviewed
      end exclusive
      true
      id
      nct-edge-f7e571b9f9b8d654f2df
      link basis
      returned_by_explicit_condition_and_posted_results_filter_query
      nct id
      NCT05579782
      occurrences
      1. context exact
        NCT05579782
        end
        11
        exact text
        NCT05579782
        start
        0
      offset unit
      unicode_code_points
      query cond
      Parathyroid Cancer
      query disease state id
      ds-parathyroid-cancer
      source file
      /Users/arunverma/Documents/ChatGPT/Cancer Statistics Website/research-data/2026-09-10/clinicaltrials-condition/round-0000/raw/cond-parathyroid-cancer-000.json
      source file sha256
      2b4988b513f0b70e7c49c0c10cabf5241c1231b8e29e89b78dc9406bd8749c8a
      source json pointer
      /studies/18/protocolSection/identificationModule/nctId
      source kind
      ctgov_condition_query
      source record id
      Source null
      source string basis
      parsed_JSON_string_unmodified
      source string sha256
      c6fe3e2dfddf26e0901e030ad55f6087d0d16e9d4ce459331796381cbea12572

    Preserved source evidence · Not medical advice