The Results of Pharyngoesophageal Segment (PES) Vibration Analysed With the Biomechanical Model Obtained by High - Speed Video Endoscopy - Central Tendency and Dispersion - Fundamental Frequency
Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.
- Measure
- MEDIAN
- Unit
- Hertz (Hz)
- Interval / dispersion
- Inter-Quartile Range
- Time frame
- 3 months
What was measured
The development of the biomechanical model of the PES in order to quantify non-stationary pharyngoesophageal vibrations and drawing conclusions on the temporal characteristics of tissue stiffness, oscillating mass, pressure, and geometric distributions within the PES. The biomechanical model identify mathematical dependencies and analyse extracted time signals of the PES opening and contours (i.e. the opening and closing of the vibrating mucosa of the PES). The PES waveform allowed us to calculate the fundamental frequency (Hz).
Groups in this outcome
The Results of PES Vibration Analysed With the Biomechanical Model - Fundamental Frequency
Patients who have undergone total laryngectomy and completed minimal their 6-month period without disease after surgery and post-operative treatments such as radiotherapy or chemotherapy. The development of the biomechanical model of the PES in order to quantify non-stationary pharyngoesophageal vibrations and drawing conclusions on the temporal characteristics of tissue stiffness, oscillating mass, pressure, and geometric distributions within the PES. The biomechanical model identify mathematical dependencies and analyse extracted time signals of the PES opening and contours (i.e. the opening and closing of the vibrating mucosa of the PES).
| Group | Source count |
|---|---|
| The Results of PES Vibration Analysed With the Biomechanical Model - Fundamental Frequency | 55 |
Reported measurements
Source class 1
| Group | Value | Spread | Lower | Upper | Comment |
|---|---|---|---|---|---|
| The Results of PES Vibration Analysed With the Biomechanical Model - Fundamental Frequency | 81.37 | Not reported | 59.17 | 102.09 | Not reported |
Complete source fields
- classes
- categories
- measurements
- group Id
- OG000
- lower Limit
- 59.17
- upper Limit
- 102.09
- value
- 81.37
- denoms
- counts
- group Id
- OG000
- value
- 55
- units
- Participants
- description
- The development of the biomechanical model of the PES in order to quantify non-stationary pharyngoesophageal vibrations and drawing conclusions on the temporal characteristics of tissue stiffness, oscillating mass, pressure, and geometric distributions within the PES. The biomechanical model identify mathematical dependencies and analyse extracted time signals of the PES opening and contours (i.e. the opening and closing of the vibrating mucosa of the PES). The PES waveform allowed us to calculate the fundamental frequency (Hz).
- dispersion Type
- Inter-Quartile Range
- groups
- description
- Patients who have undergone total laryngectomy and completed minimal their 6-month period without disease after surgery and post-operative treatments such as radiotherapy or chemotherapy. The development of the biomechanical model of the PES in order to quantify non-stationary pharyngoesophageal vibrations and drawing conclusions on the temporal characteristics of tissue stiffness, oscillating mass, pressure, and geometric distributions within the PES. The biomechanical model identify mathematical dependencies and analyse extracted time signals of the PES opening and contours (i.e. the opening and closing of the vibrating mucosa of the PES).
- id
- OG000
- title
- The Results of PES Vibration Analysed With the Biomechanical Model - Fundamental Frequency
- param Type
- MEDIAN
- reporting Status
- POSTED
- time Frame
- 3 months
- title
- The Results of Pharyngoesophageal Segment (PES) Vibration Analysed With the Biomechanical Model Obtained by High - Speed Video Endoscopy - Central Tendency and Dispersion - Fundamental Frequency
- type
- PRIMARY
- unit Of Measure
- Hertz (Hz)
Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f