Skip to content
← Full study record

NCT03686215 · OUTCOME

Detection and Conversion of Positive Margins.

Investigation of Novel Surgical Imaging for Tumor Excision · Source last updated 2023-08-24

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
NUMBER
Unit
percentage of participants
Interval / dispersion
95% Confidence Interval
Time frame
Day 1, during surgery

What was measured

Detection of positive margins: Percentage of patients with positive margins after standard of care breast-conserving surgery, all had LUM Imaging System signals above the threshold in the cavity as defined by the tumor detection algorithm. Conversion of positive margins: Percentage of patients with positive margins after standard of care breast-conserving surgery resulted in the negative margin after LUM Imaging System was used. The system was used during the surgery, but the assessment of the outcomes was unknown until the pathology report was available.

Analysis population: modified intent to treat population (mITT) includes subjects injected with LUM015 and LUM Imaging was performed

Groups in this outcome

Device Intervention: LUM Imaging System Used During Surgery

The LUM Imaging Device was used to examine inside the lumpectomy cavity to determine if the dye indicated any areas that might contain residual tumor. If the imaging tested positive for the cancer cells remaining in the lumpectomy cavity, the surgeon would remove an additional piece of tissue. This process was continued until a negative reading from the device was obtained or a maximum of 2 shaves of additional tissue had been removed. Patients in this arm received the study drug, LUM015. Study Device Arm: LUM015 was administered 2 to 6 hours prior to surgery. The LUM Imaging device was used to assist in the removal of additional tumor tissue.

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Device Intervention: LUM Imaging System Used During Surgery357

Reported measurements

Percentage among participants having positive margins after SoC all detected by LUM Imaging System

Analysis denominator · Participants

GroupSource count
Device Intervention: LUM Imaging System Used During Surgery62
Values in percentage of participants · Interval/dispersion: 95% Confidence Interval
GroupValueSpreadLowerUpperComment
Device Intervention: LUM Imaging System Used During Surgery16.1Not reported8.027.7Not reported
Percentage of participants with positive SOC margins converted to negative with LUM Imaging System

Analysis denominator · Participants

GroupSource count
Device Intervention: LUM Imaging System Used During Surgery62
Values in percentage of participants · Interval/dispersion: 95% Confidence Interval
GroupValueSpreadLowerUpperComment
Device Intervention: LUM Imaging System Used During Surgery14.5Not reported6.925.8Not reported
Complete source fields
classes
  1. categories
    1. measurements
      1. group Id
        OG000
        lower Limit
        8.0
        upper Limit
        27.7
        value
        16.1
    denoms
    1. counts
      1. group Id
        OG000
        value
        62
      units
      Participants
    title
    Percentage among participants having positive margins after SoC all detected by LUM Imaging System
  2. categories
    1. measurements
      1. group Id
        OG000
        lower Limit
        6.9
        upper Limit
        25.8
        value
        14.5
    denoms
    1. counts
      1. group Id
        OG000
        value
        62
      units
      Participants
    title
    Percentage of participants with positive SOC margins converted to negative with LUM Imaging System
denoms
  1. counts
    1. group Id
      OG000
      value
      357
    units
    Participants
description
Detection of positive margins: Percentage of patients with positive margins after standard of care breast-conserving surgery, all had LUM Imaging System signals above the threshold in the cavity as defined by the tumor detection algorithm. Conversion of positive margins: Percentage of patients with positive margins after standard of care breast-conserving surgery resulted in the negative margin after LUM Imaging System was used. The system was used during the surgery, but the assessment of the outcomes was unknown until the pathology report was available.
dispersion Type
95% Confidence Interval
groups
  1. description
    The LUM Imaging Device was used to examine inside the lumpectomy cavity to determine if the dye indicated any areas that might contain residual tumor. If the imaging tested positive for the cancer cells remaining in the lumpectomy cavity, the surgeon would remove an additional piece of tissue. This process was continued until a negative reading from the device was obtained or a maximum of 2 shaves of additional tissue had been removed. Patients in this arm received the study drug, LUM015. Study Device Arm: LUM015 was administered 2 to 6 hours prior to surgery. The LUM Imaging device was used to assist in the removal of additional tumor tissue.
    id
    OG000
    title
    Device Intervention: LUM Imaging System Used During Surgery
param Type
NUMBER
population Description
modified intent to treat population (mITT) includes subjects injected with LUM015 and LUM Imaging was performed
reporting Status
POSTED
time Frame
Day 1, during surgery
title
Detection and Conversion of Positive Margins.
type
SECONDARY
unit Of Measure
percentage of participants

Download exact source JSON → · Snapshot ctgov-results-191f4516d4760045304b24a0

Preserved source evidence · Not medical advice