Skip to content
← Full study record

NCT03458234 · OUTCOME

Assess Early Efficacy

RAD 1801: Pilot Study of Intra-Urethral Radiotransponder Beacon Guided Focal Prostate Stereotactic Body Radiotherapy · Source last updated 2024-05-20

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
Not reported
Unit
Not reported
Interval / dispersion
Not reported
Time frame
Within 6 months of completion of radiation therapy

What was measured

Clinically assess early efficacy for men receiving focal prostate SBRT for low and low-intermediate risk prostate cancer.Efficacy will be defined as the absence of biochemically detected (via PSA lab testing) prostate cancer or clinically detected prostate cancer

Analysis population: 5 patients signed consent, 1 patient withdrew consent prior to start of treatment. The funding source informed they are no longer manufacturing radiotransponder. No similar product. Therefore, no longer proceeding with study and no data collected.

Groups in this outcome

Focal SBRT With Intra-urethral Radiotransponder

This study will enroll patients that have a confirmed histology of prostate cancer. They will undergo a 3T MRI scan as well as a CT simulation with 16 French Foley Catheter containing dummy beacons for treatment planning purposes. The patient will then receive focal stereotactic body radiotherapy (SBRT) at a dose of 40 gy in 5 total fractions. Patients will be followed for 24 total months with specific follow-ups at 3, 6, 9, 12, 18, and 24 months. 16 French Foley Catheter: A Foley catheter is a medical apparatus that creates a passageway for the drainage and collection of urine. This type of catheter is made of a pliable material that indwells into an individual's bladder by way of the urethra. Featuring two separate channels down the tube, Foley catheters allow absolute stability and safe extraction. One channel of the catheter, by method of a balloon, is stabilized in a bladder; the other channel allows for the passage and collection of urine, by means of a leg bag or bedside drainage bag. Foley catheters are usually constructed out of either silicone or latex.

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Focal SBRT With Intra-urethral Radiotransponder0

Reported measurements

No numerical measurement classes were posted for this outcome. Missing is not zero.

Complete source fields
denoms
  1. counts
    1. group Id
      OG000
      value
      0
    units
    Participants
description
Clinically assess early efficacy for men receiving focal prostate SBRT for low and low-intermediate risk prostate cancer.Efficacy will be defined as the absence of biochemically detected (via PSA lab testing) prostate cancer or clinically detected prostate cancer
groups
  1. description
    This study will enroll patients that have a confirmed histology of prostate cancer. They will undergo a 3T MRI scan as well as a CT simulation with 16 French Foley Catheter containing dummy beacons for treatment planning purposes. The patient will then receive focal stereotactic body radiotherapy (SBRT) at a dose of 40 gy in 5 total fractions. Patients will be followed for 24 total months with specific follow-ups at 3, 6, 9, 12, 18, and 24 months. 16 French Foley Catheter: A Foley catheter is a medical apparatus that creates a passageway for the drainage and collection of urine. This type of catheter is made of a pliable material that indwells into an individual's bladder by way of the urethra. Featuring two separate channels down the tube, Foley catheters allow absolute stability and safe extraction. One channel of the catheter, by method of a balloon, is stabilized in a bladder; the other channel allows for the passage and collection of urine, by means of a leg bag or bedside drainage bag. Foley catheters are usually constructed out of either silicone or latex.
    id
    OG000
    title
    Focal SBRT With Intra-urethral Radiotransponder
population Description
5 patients signed consent, 1 patient withdrew consent prior to start of treatment. The funding source informed they are no longer manufacturing radiotransponder. No similar product. Therefore, no longer proceeding with study and no data collected.
reporting Status
POSTED
time Frame
Within 6 months of completion of radiation therapy
title
Assess Early Efficacy
type
SECONDARY

Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f

Preserved source evidence · Not medical advice