Skip to content
← Study library

NCT02307552 · REGISTRY CONDITION SEARCH

Transurethral Ultrasonic Imaging For Detection and Classification of Prostate Cancer

Found through the registry condition index, not selected as a treatment recommendation. This discovery collection was restricted to studies with posted results.

Phase
NA
Status at capture
TERMINATED
Registry last update
2017-07-27

This study is being performed to verify the ability to use minimally invasive transurethral ultrasonic imaging technology for the purpose of identifying prostate cancer. Transurethral ultrasonic prostate imaging, may in the future, be used for detection and monitoring these disease processes to minimize the need for obtaining surgical biopsy specimens. The hypothesis is that tissue-density variations, as revealed in diagnostic ultrasonic imaging, results in unique image signatures for identification of prostate cancer. This imaging procedure provides a multifaceted view of the entire in-situ gland. The current use of Prostate Specific Antigen (PSA) for determining the likelihood of presence of cancer in the prostate gland requires interpretation and has a good but limited to predict prostate cancer on biopsy, with significant false prediction rates. More importantly as a blood test, the PSA test lacks the ability to pinpoint the location of the cancer within the prostate gland. Preliminary study findings have suggested that "Transurethral Ultrasonic Scanning" (TUUS) presents the desired improved diagnostic sensitivity for detection of cancer within the imaged prostate gland, and has the intrinsic capability to provide high resolution images of the transverse and future three-dimensional views of the entire gland better than currently used Transurethral Ultrasound (TRUS). Two important goals of the practicality of this minimally invasive technology will be assessed by this study. 1. The ability of TUUS to directly detect prostate cancer locations in the prostate. 2. The use of TUUS to successfully guide the prostate needle biopsy to cancer loci with a high rate accuracy.

Open the original ClinicalTrials.gov record → · Download preserved record

What did the study report?

Outcomes, safety and baseline populations are separate source sections. Quality-of-life measures appear under their original outcome titles.

Who could take part
eligibility Criteria
Inclusion Criteria: * Men undergoing a standard of care radical prostatectomy for prostate cancer. * Aged \> 40 years old. * Men who have a serious prostate obstruction, are excluded due to the difficulty of catheter insertion. Exclusion Criteria: * Women are excluded as they do not have a prostate gland. * Minors are excluded as prostate cancer is generally found only in men aged \> 40 years old
healthy Volunteers
false
maximum Age
80 Years
minimum Age
40 Years
sex
MALE
std Ages
  1. ADULT
  2. OLDER_ADULT
Treatment arms and interventions
arm Groups
  1. description
    All patients in the study will receive a scan of their prostate with the novel UreScan machine. All scans will be evaluated in their accuracy of detecting cancer loci within the prostate as compared to histopathological reviews of the prostate post robotic prostatectomy.
    intervention Names
    1. Device: UreScan
    label
    All patients
    type
    EXPERIMENTAL
interventions
  1. arm Group Labels
    1. All patients
    description
    The TUUS Foley/catheter will be inserted into the urethra via the ultrasound visualization onto the apex prostate, and the ultrasound extended through the urethra until the bladder neck and stopped. This is recorded twice automatically, and this should take 5-10 minutes for completion, and the prostate ultrasound data stored in memory. The ultrasound/subject interaction is now complete, and the study should add 30-60 minutes to the preoperative visit. No local or general anesthesia is used. The subject will be given 500 mg of Ciprofloxacin as a preventative measure against a urinary tract infection.
    name
    UreScan
    type
    DEVICE
Study design
allocation
NA
intervention Model
SINGLE_GROUP
masking Info
masking
NONE
primary Purpose
DIAGNOSTIC
Enrollment
count
1
type
ACTUAL
Registered outcome plans (not posted results)
primary Outcomes
  1. description
    The primary objective of this Institutional Review Board -controlled study is to determine if Trans urethral ultrasound can be used to identify prostate cancer, thus avoiding prostate needle biopsies for diagnosis
    measure
    Measure Novel Transurethral Ultrasound Signatures to Detect Prostate Cancer
    time Frame
    one year
Full study description
brief Summary
This study is being performed to verify the ability to use minimally invasive transurethral ultrasonic imaging technology for the purpose of identifying prostate cancer. Transurethral ultrasonic prostate imaging, may in the future, be used for detection and monitoring these disease processes to minimize the need for obtaining surgical biopsy specimens. The hypothesis is that tissue-density variations, as revealed in diagnostic ultrasonic imaging, results in unique image signatures for identification of prostate cancer. This imaging procedure provides a multifaceted view of the entire in-situ gland. The current use of Prostate Specific Antigen (PSA) for determining the likelihood of presence of cancer in the prostate gland requires interpretation and has a good but limited to predict prostate cancer on biopsy, with significant false prediction rates. More importantly as a blood test, the PSA test lacks the ability to pinpoint the location of the cancer within the prostate gland. Preliminary study findings have suggested that "Transurethral Ultrasonic Scanning" (TUUS) presents the desired improved diagnostic sensitivity for detection of cancer within the imaged prostate gland, and has the intrinsic capability to provide high resolution images of the transverse and future three-dimensional views of the entire gland better than currently used Transurethral Ultrasound (TRUS). Two important goals of the practicality of this minimally invasive technology will be assessed by this study. 1. The ability of TUUS to directly detect prostate cancer locations in the prostate. 2. The use of TUUS to successfully guide the prostate needle biopsy to cancer loci with a high rate accuracy.
detailed Description
The Purpose of the Research The primary objective of this Institutional Review Board-controlled study is to determine if the presently manually-read results of TUUS data obtained with the novel UreScan device can be correlated with pathologist findings in a harvested prostate gland from an individual with diagnosed prostate disease. If successful, a future Institutional Review Board study will explore the use of computer software to examine the 256 transverse image slices of a large number of prostate cancer patients to establish the clinical applicability of TUUS for screening and assessment of individuals with elevated levels of PSA and/or positive digital rectal examinations (DRE), potentially reducing the number of future biopsy examinations with false-positive findings. Background Information The current use of Prostate Specific Antigen for determining the likelihood of presence of cancer in the prostate gland has been shown to be seriously flawed. Multiple studies reviewing the findings of referred biopsies, based on elevated PSA levels, resulted in as many as 70% false positive findings for cancer. Improved rapid, minimally-invasive, low-cost methodology and technology should be developed to provide diagnostic cancer findings that have higher sensitivity and specificity is the objective goal of the present research. Preliminary study findings have suggested that "Transurethral Ultrasonic Scanning" (TUUS) presents the desired improved diagnostic sensitivity for detection of cancer within the imaged prostate gland and has the intrinsic capability to provide high resolution images of the transverse and future three-dimensional views of the entire gland. Two important goals of this minimally invasive technology will be assessed by this study. 1. The ability of TUUS to directly detect prostate cancer in situ in the prostate. 2. The use of TUUS to successfully guide the prostate needle biopsy to cancer loci with a high rate accuracy. In a 2003 study by Holmes et al, the TUUS device was tested on 2 patients who had seeds implanted for prostate cancer. TUUS revealed more seeds (82%, 84%) than standard TRUS (63%, 65%) in the 2 patients. These simple cases demonstrated the feasibility of providing transverse images of the entire prostate gland. Holmes postulated that this procedure would have to be automated to achieve any clinical utility value and the project essentially was abandoned by Mayo. The TUUS/"UreScan" system is a marriage of an off label usage of the FDA approved vascular probe, placed inside a standard foley catheter which is inserted into the penis onto the prostate to the neck of the bladder. The ultrasound probe travels the length of the prostate (\~4-8cm) within the sheath of the catheter and images the entire prostate with ultrasound. The travel of the ultrasound probe is controlled by a small motor which is driven from outside the catheter and patient as well. This motor driven probe offers the possibility of accurate and reproducible ultrasounds of the prostate, as the patient's prostate apex is used the anchor point for study. Refinements to the TUUS system include: 1. A Foley type introducer should be used for placing the intravascular ultrasound transducer in the prostatic urethral region to be imaged 2. Use of a fixed-position, ultrasonic coupling gel-coated Introducer to eliminate the possibility of urethral abrasion or trauma as might otherwise occur without the Introducer when moving the transducer within the prostatic imaging region. 3. Insertion into the Introducer of the wire-rotationally-driven ultrasonic transducer as coated with sterile water ultrasonic coupling between the transducer and introducer 4. The examiner would then initiate the automated scanning procedure with analog/digital video data for each of 256 transverse axial image slices of the prostate gland. The scanning of the gland can be stopped or started at the election of the examiner 5. A video-media record of the images derived from the procedure is available to an experienced reader for interpretation. The initial UreScan hydrophone verified specifications included: 1. 256 transverse, automatically axially advanced, image slices. 2. Approximately 267 megabits of video data. 3. Diagnostic ultrasound scanning of 100 revolutions per minute at 9.0 M Megahertz. 4. Radial penetration of 6 cm. The scanner features: 1. The amplitude of reflected ultrasonic echoes from biological tissue, as displayed by a density-based oscillogram is directly proportional to the density of the tissue being insonated in an adjusted flat far-gain ultrasonic system. 2. Longitudinal time-related, ultrasonic densitometry and image-registered comparisons of sonograms have demonstrated progression and/or regression of disease consistent with efficacy of treatment procedures. This facilitates future "wait and watch surveillance" of known or suspected lesions while potentially minimizing and/or eliminating unnecessary surgical biopsy tissues procedures 3. The reflected echo waveform and sonogram has been shown to be unique for each type of disease entity. In prostate disease, there is a unique difference between the image-markers for prostate cancer and normal tissue. The present study protocol is to determine if image-markers for cancer and other unique prostate pathology can be specifically identified. Further clinical studies will be required to determine sensitivity, specificity, accuracy and (+/-) predictor values of this procedure. Additional studies will be required to determine if the amplitude of the image-markers could be used for determining the approximate stage of the image detected disease processes.
Source references
references
  1. citation
    Holmes DR 3rd, Davis BJ, Bruce CJ, Robb RA. 3D visualization, analysis, and treatment of the prostate using trans-urethral ultrasound. Comput Med Imaging Graph. 2003 Sep-Oct;27(5):339-49. doi: 10.1016/s0895-6111(02)00102-7.
    pmid
    12821027
    type
    BACKGROUND
Source notices and limitations
    Discovery and provenance
    1. release id
      ctgov-registry-1336d216cbd1bbff780dac70
      edge id
      nct-edge-81be671677c71ac76a17
      requested nct id
      NCT02307552
      primary nct id
      NCT02307552
      source kind
      ctgov_condition_query
      source record id
      Source null
      source file sha256
      308f79635904744c3081b7bece1bbf864685110f5917c0840a211e0e58d7fefc
      payload sha256
      895bb19853c03c74c9bfb8540116d4903b3a9f4b7dff40ea072e27d18a66c825
      payload
      clinical indication matching status
      condition_index_match_asserted_by_registry_not_reviewed
      end exclusive
      true
      id
      nct-edge-81be671677c71ac76a17
      link basis
      returned_by_explicit_condition_and_posted_results_filter_query
      nct id
      NCT02307552
      occurrences
      1. context exact
        NCT02307552
        end
        11
        exact text
        NCT02307552
        start
        0
      offset unit
      unicode_code_points
      query cond
      Urethral Cancer
      query disease state id
      ds-urethral-cancer
      source file
      /Users/arunverma/Documents/ChatGPT/Cancer Statistics Website/research-data/2026-09-10/clinicaltrials-condition/round-0000/raw/cond-urethral-cancer-000.json
      source file sha256
      308f79635904744c3081b7bece1bbf864685110f5917c0840a211e0e58d7fefc
      source json pointer
      /studies/28/protocolSection/identificationModule/nctId
      source kind
      ctgov_condition_query
      source record id
      Source null
      source string basis
      parsed_JSON_string_unmodified
      source string sha256
      94da853fcdd7e39bd89e7fcd5d123ceb11287c7c4d934564143a3865f3dd104c

    Preserved source evidence · Not medical advice