Skip to content
← Full study record

NCT01829711 · OUTCOME

Area Under the Plasma Concentration-time Curve Extrapolated (AUCExt) of Moxetumomab Pasudotox

Moxetumomab Pasudotox for Advanced Hairy Cell Leukemia · Source last updated 2020-04-08

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
MEAN
Unit
ng*hr/mL
Interval / dispersion
Standard Deviation
Time frame
Cycle 1 Day 1 (pre-dose; 5 mins and 3 hr post dose); Cycle 1 Day 5 (pre-dose; 5 mins, 1 hr, 3 hr, and 6 hrs post dose); and Cycle 2 Day 1 (pre-dose; 5 mins and 3 hr post dose)

What was measured

The AUCExt of moxetumomab pasudotox is reported.

Analysis population: The PK population included all participants who received at least 1 dose of moxetumomab pasudotox and provided at least 1 baseline and post-baseline concentration-time data point.

Groups in this outcome

Moxetumomab Pasudotox 40 µg/kg

Participants received intravenous infusion of moxetumomab pasudotox 40 µg/kg on Days 1, 3, and 5 of each 28-day cycle for up to 6 cycles, until documentation of complete response, progressive disease, initiation of alternate therapy, or unacceptable toxicity.

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Moxetumomab Pasudotox 40 µg/kg80

Reported measurements

Cycle 1 Day 1

Analysis denominator · Participants

GroupSource count
Moxetumomab Pasudotox 40 µg/kg6
Values in ng*hr/mL · Interval/dispersion: Standard Deviation
GroupValueSpreadLowerUpperComment
Moxetumomab Pasudotox 40 µg/kg13.23.04Not reportedNot reportedNot reported
Cycle 1 Day 5

Analysis denominator · Participants

GroupSource count
Moxetumomab Pasudotox 40 µg/kg49
Values in ng*hr/mL · Interval/dispersion: Standard Deviation
GroupValueSpreadLowerUpperComment
Moxetumomab Pasudotox 40 µg/kg14.35.72Not reportedNot reportedNot reported
Cycle 2 Day 1

Analysis denominator · Participants

GroupSource count
Moxetumomab Pasudotox 40 µg/kg22
Values in ng*hr/mL · Interval/dispersion: Standard Deviation
GroupValueSpreadLowerUpperComment
Moxetumomab Pasudotox 40 µg/kg20.27.62Not reportedNot reportedNot reported
Complete source fields
classes
  1. categories
    1. measurements
      1. group Id
        OG000
        spread
        3.04
        value
        13.2
    denoms
    1. counts
      1. group Id
        OG000
        value
        6
      units
      Participants
    title
    Cycle 1 Day 1
  2. categories
    1. measurements
      1. group Id
        OG000
        spread
        5.72
        value
        14.3
    denoms
    1. counts
      1. group Id
        OG000
        value
        49
      units
      Participants
    title
    Cycle 1 Day 5
  3. categories
    1. measurements
      1. group Id
        OG000
        spread
        7.62
        value
        20.2
    denoms
    1. counts
      1. group Id
        OG000
        value
        22
      units
      Participants
    title
    Cycle 2 Day 1
denoms
  1. counts
    1. group Id
      OG000
      value
      80
    units
    Participants
description
The AUCExt of moxetumomab pasudotox is reported.
dispersion Type
Standard Deviation
groups
  1. description
    Participants received intravenous infusion of moxetumomab pasudotox 40 µg/kg on Days 1, 3, and 5 of each 28-day cycle for up to 6 cycles, until documentation of complete response, progressive disease, initiation of alternate therapy, or unacceptable toxicity.
    id
    OG000
    title
    Moxetumomab Pasudotox 40 µg/kg
param Type
MEAN
population Description
The PK population included all participants who received at least 1 dose of moxetumomab pasudotox and provided at least 1 baseline and post-baseline concentration-time data point.
reporting Status
POSTED
time Frame
Cycle 1 Day 1 (pre-dose; 5 mins and 3 hr post dose); Cycle 1 Day 5 (pre-dose; 5 mins, 1 hr, 3 hr, and 6 hrs post dose); and Cycle 2 Day 1 (pre-dose; 5 mins and 3 hr post dose)
title
Area Under the Plasma Concentration-time Curve Extrapolated (AUCExt) of Moxetumomab Pasudotox
type
SECONDARY
unit Of Measure
ng*hr/mL

Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f

Preserved source evidence · Not medical advice