NCT01194466 · OUTCOME

Change in Pain Intensity in Head/Neck Cancer Area: 10cm Visual Analog Scale (VAS)

Transcutaneous Electrical Nerve Stimulation (TENS) and Head and Neck Cancer Pain (HNC) (TENS & HNC) · Source last updated 2019-09-17

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
MEAN
Unit
change units on a VAS scale
Interval / dispersion
Standard Deviation
Time frame
The change in VAS pain score was assessed within one study visit for each of the 3 study TENS conditions

What was measured

Participants rated 0-10 pain intensity in head/neck cancer area using one number (where their disease was located) by a vertical line on a horizontal 10-cm visual analog scale (VAS) from 0 "no pain" to 10 "worst possible pain." Possible scores ranged from 0-10 (10=worse pain). VAS was assessed two times each visit: (1) Pre-VAS: start of visit, (2) Post-VAS: end of the visit. The outcome measure was each person's change in pain: Pre-VAS minus Post-VAS, to create VAS change score. An average of all participants' VAS change score was calculated for each TENS condition (Active, Placebo, No TENS) and used as the dependent measure.

Analysis population: The sample was adults (18 or greater) years old with oropharyngeal or laryngeal cancer.

Groups in this outcome

Active TENS

Each participant received an Active TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the Active TENS condition. Active TENS was delivered for 30 minutes at a frequency of 125Hz and a pulse duration of 100 2s on continuous mode output (calibrated using an oscilloscope before the study). Transcutaneous electrical nerve stimulation intensity was increased by the allocator until patients reported a ''maximally strong but comfortable sensation'' to ensure an analgesic effect.

Placebo TENS

Each participant received an Placebo TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the Placebo TENS condition. Placebo TENS parameters were identical to active TENS (125 Hz, 100 2s). A novel, transient placebo TENS unit, previously tested and validated, was used. The intensity was increased until patients first felt ''any sensation at all (sensory threshold)'' in any electrode (ie, they did not have to reach sensory threshold in all electrodes). The placebo device then provided a current for 30 seconds and decreased gradually over 15 seconds to 0 output (ie, 45 seconds from the first sensory threshold). An indicator light remained on for the remainder of the visit so it appeared to the participant and outcomes assessor that the unit was still producing current.

No TENS

Each participant received a No TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the No TENS condition. No TENS parameters were identical to active and placebo TENS, except that (1) the unit was never turned on and (2) participants were told that the unit was not on.

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Active TENS40
Placebo TENS40
No TENS40

Reported measurements

Source class 1
Values in change units on a VAS scale · Interval/dispersion: Standard Deviation
GroupValueSpreadLowerUpperComment
Active TENS-1.41.3Not reportedNot reportedNot reported
Placebo TENS-0.61.1Not reportedNot reportedNot reported
No TENS0.10.9Not reportedNot reportedNot reported
Complete source fields
classes
  1. categories
    1. measurements
      1. group Id
        OG000
        spread
        1.3
        value
        -1.4
      2. group Id
        OG001
        spread
        1.1
        value
        -0.6
      3. group Id
        OG002
        spread
        0.9
        value
        0.1
denoms
  1. counts
    1. group Id
      OG000
      value
      40
    2. group Id
      OG001
      value
      40
    3. group Id
      OG002
      value
      40
    units
    Participants
description
Participants rated 0-10 pain intensity in head/neck cancer area using one number (where their disease was located) by a vertical line on a horizontal 10-cm visual analog scale (VAS) from 0 "no pain" to 10 "worst possible pain." Possible scores ranged from 0-10 (10=worse pain). VAS was assessed two times each visit: (1) Pre-VAS: start of visit, (2) Post-VAS: end of the visit. The outcome measure was each person's change in pain: Pre-VAS minus Post-VAS, to create VAS change score. An average of all participants' VAS change score was calculated for each TENS condition (Active, Placebo, No TENS) and used as the dependent measure.
dispersion Type
Standard Deviation
groups
  1. description
    Each participant received an Active TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the Active TENS condition. Active TENS was delivered for 30 minutes at a frequency of 125Hz and a pulse duration of 100 2s on continuous mode output (calibrated using an oscilloscope before the study). Transcutaneous electrical nerve stimulation intensity was increased by the allocator until patients reported a ''maximally strong but comfortable sensation'' to ensure an analgesic effect.
    id
    OG000
    title
    Active TENS
  2. description
    Each participant received an Placebo TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the Placebo TENS condition. Placebo TENS parameters were identical to active TENS (125 Hz, 100 2s). A novel, transient placebo TENS unit, previously tested and validated, was used. The intensity was increased until patients first felt ''any sensation at all (sensory threshold)'' in any electrode (ie, they did not have to reach sensory threshold in all electrodes). The placebo device then provided a current for 30 seconds and decreased gradually over 15 seconds to 0 output (ie, 45 seconds from the first sensory threshold). An indicator light remained on for the remainder of the visit so it appeared to the participant and outcomes assessor that the unit was still producing current.
    id
    OG001
    title
    Placebo TENS
  3. description
    Each participant received a No TENS intervention at one clinic visit, separated approximately one week from the other 2 TENS condition visits. In other words, all participants received the No TENS condition. No TENS parameters were identical to active and placebo TENS, except that (1) the unit was never turned on and (2) participants were told that the unit was not on.
    id
    OG002
    title
    No TENS
param Type
MEAN
population Description
The sample was adults (18 or greater) years old with oropharyngeal or laryngeal cancer.
reporting Status
POSTED
time Frame
The change in VAS pain score was assessed within one study visit for each of the 3 study TENS conditions
title
Change in Pain Intensity in Head/Neck Cancer Area: 10cm Visual Analog Scale (VAS)
type
PRIMARY
unit Of Measure
change units on a VAS scale

Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f

Preserved source evidence · Not medical advice