NCT00661570 · OUTCOME
Voice Quality
Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.
- Measure
- MEAN
- Unit
- Units on a scale
- Interval / dispersion
- Standard Deviation
- Time frame
- at 3 months or device change (whichever was first)
What was measured
Subjective patient opinion about 5 voice related items (intelligibility face to face and on the phone, loudness, pitch and fluency). The best value is 5 and the worst value is 20.
Analysis population: 23 patients completed the structured questionnaires about the voice prosthesis. One patient received the wrong voice prosthesis after inclusion. Two patients had unsolvable leakage around the Provox Vega 20, which is 2.5 French smaller in outer diameter than their previous Provox2 voice prosthesis.
Groups in this outcome
Provox Vega 20
26 Patients who normally use a Provox2 voice prosthesis, were asked to use a new Vega voice prosthesis with an outer diameter of 20 French.
| Group | Source count |
|---|---|
| Provox Vega 20 | 23 |
Reported measurements
Source class 1
| Group | Value | Spread | Lower | Upper | Comment |
|---|---|---|---|---|---|
| Provox Vega 20 | 8.4 | 4.4 | Not reported | Not reported | Not reported |
Complete source fields
- classes
- categories
- measurements
- group Id
- OG000
- spread
- 4.4
- value
- 8.4
- denoms
- counts
- group Id
- OG000
- value
- 23
- units
- Participants
- description
- Subjective patient opinion about 5 voice related items (intelligibility face to face and on the phone, loudness, pitch and fluency). The best value is 5 and the worst value is 20.
- dispersion Type
- Standard Deviation
- groups
- description
- 26 Patients who normally use a Provox2 voice prosthesis, were asked to use a new Vega voice prosthesis with an outer diameter of 20 French.
- id
- OG000
- title
- Provox Vega 20
- param Type
- MEAN
- population Description
- 23 patients completed the structured questionnaires about the voice prosthesis. One patient received the wrong voice prosthesis after inclusion. Two patients had unsolvable leakage around the Provox Vega 20, which is 2.5 French smaller in outer diameter than their previous Provox2 voice prosthesis.
- reporting Status
- POSTED
- time Frame
- at 3 months or device change (whichever was first)
- title
- Voice Quality
- type
- SECONDARY
- unit Of Measure
- Units on a scale
Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f