Skip to content
← Full study record

NCT00652626 · OUTCOME

Area Under the Plasma Concentration-time Curve From Time Zero to Infinity

Pharmacokinetics and Safety Study of Azacitidine in Cancer Patients With and Without Impaired Renal Function · Source last updated 2019-11-19

Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.

Measure
GEOMETRIC_MEAN
Unit
ng*hr/mL
Interval / dispersion
Geometric Coefficient of Variation
Time frame
Day 1 at predose, 5, 15, 30, 45 minutes and 1, 1.5, 2, 2.5, 3, 3.5, 4, 6, and 8 hours post-dose

What was measured

The area under the plasma concentration-time curve from time zero to infinity (AUC0-inf) for azacitidine after a single dose, calculated by the linear trapezoidal rule and extrapolated to infinity according to the following equation: AUC0-inf = AUC0-t + (Ct/ke), where Ct is the last quantifiable concentration and ke = elimination rate constant.

Analysis population: Pharmacokinetic Population, consisting of all participants with evaluable plasma or urine concentration data for azacitidine. This analysis was performed for participants with normal renal function only.

Groups in this outcome

Azacitidine 25 mg/m^2

Participants with normal renal function (defined as creatinine clearance \> 80 mL/min/1.73m\^2) received a single subcutaneous dose of azacitidine 25 mg/m\^2 on Day 1.

Azacitidine 50 mg/m^2

Participants with normal renal function received a single subcutaneous dose of azacitidine 50 mg/m\^2 on Day 1.

Azacitidine 75 mg/m^2

Participants with normal renal function received subcutaneous doses of azacitidine 75 mg/m\^2 on Days 1 to 5.

Azacitidine 100 mg/m^2

Participants with normal renal function received a single subcutaneous dose of azacitidine 100 mg/m\^2 on Day 1.

Group identifiers and denominators belong to this outcome only. They may differ in another outcome or in safety reporting.

Analysis denominator · Participants

GroupSource count
Azacitidine 25 mg/m^25
Azacitidine 50 mg/m^25
Azacitidine 75 mg/m^26
Azacitidine 100 mg/m^25

Reported measurements

Source class 1
Values in ng*hr/mL · Interval/dispersion: Geometric Coefficient of Variation
GroupValueSpreadLowerUpperComment
Azacitidine 25 mg/m^2460.4725.79Not reportedNot reportedNot reported
Azacitidine 50 mg/m^2897.4230.93Not reportedNot reportedNot reported
Azacitidine 75 mg/m^2945.5039.05Not reportedNot reportedNot reported
Azacitidine 100 mg/m^21533.3723.96Not reportedNot reportedNot reported

Source statistical analyses

Group order, estimate direction, methods and comments are retained. No treatment ranking is inferred.

  1. ci Lower Limit
    63.8
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    148.8
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 50 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG001
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    97.4
  2. ci Lower Limit
    45.7
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    102.7
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 75 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG002
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    68.5
  3. ci Lower Limit
    54.5
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    127.1
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 100 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG003
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    83.2
Complete source fields
analyses
  1. ci Lower Limit
    63.8
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    148.8
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 50 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG001
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    97.4
  2. ci Lower Limit
    45.7
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    102.7
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 75 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG002
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    68.5
  3. ci Lower Limit
    54.5
    ci Num Sides
    TWO_SIDED
    ci Pct Value
    90
    ci Upper Limit
    127.1
    estimate Comment
    Ratio of geometric mean is calculated as Azacitidine 100 mg/m\^2 / Azacitidine 25 mg/m\^2 and expressed as a percentage.
    group Description
    Geometric means, ratio and 90% CI of ratio of geometric means are from one way analysis of variance models on the nature log-transformed dose-normalized AUC0-inf, obtained on Day 1. Azacitidine 25 mg/m\^2 is the reference group for comparisons.
    group Ids
    1. OG000
    2. OG003
    non Inferiority Type
    SUPERIORITY_OR_OTHER_LEGACY
    param Type
    Ratio (%) of Geometric Means
    param Value
    83.2
classes
  1. categories
    1. measurements
      1. group Id
        OG000
        spread
        25.79
        value
        460.47
      2. group Id
        OG001
        spread
        30.93
        value
        897.42
      3. group Id
        OG002
        spread
        39.05
        value
        945.50
      4. group Id
        OG003
        spread
        23.96
        value
        1533.37
denoms
  1. counts
    1. group Id
      OG000
      value
      5
    2. group Id
      OG001
      value
      5
    3. group Id
      OG002
      value
      6
    4. group Id
      OG003
      value
      5
    units
    Participants
description
The area under the plasma concentration-time curve from time zero to infinity (AUC0-inf) for azacitidine after a single dose, calculated by the linear trapezoidal rule and extrapolated to infinity according to the following equation: AUC0-inf = AUC0-t + (Ct/ke), where Ct is the last quantifiable concentration and ke = elimination rate constant.
dispersion Type
Geometric Coefficient of Variation
groups
  1. description
    Participants with normal renal function (defined as creatinine clearance \> 80 mL/min/1.73m\^2) received a single subcutaneous dose of azacitidine 25 mg/m\^2 on Day 1.
    id
    OG000
    title
    Azacitidine 25 mg/m^2
  2. description
    Participants with normal renal function received a single subcutaneous dose of azacitidine 50 mg/m\^2 on Day 1.
    id
    OG001
    title
    Azacitidine 50 mg/m^2
  3. description
    Participants with normal renal function received subcutaneous doses of azacitidine 75 mg/m\^2 on Days 1 to 5.
    id
    OG002
    title
    Azacitidine 75 mg/m^2
  4. description
    Participants with normal renal function received a single subcutaneous dose of azacitidine 100 mg/m\^2 on Day 1.
    id
    OG003
    title
    Azacitidine 100 mg/m^2
param Type
GEOMETRIC_MEAN
population Description
Pharmacokinetic Population, consisting of all participants with evaluable plasma or urine concentration data for azacitidine. This analysis was performed for participants with normal renal function only.
reporting Status
POSTED
time Frame
Day 1 at predose, 5, 15, 30, 45 minutes and 1, 1.5, 2, 2.5, 3, 3.5, 4, 6, and 8 hours post-dose
title
Area Under the Plasma Concentration-time Curve From Time Zero to Infinity
type
PRIMARY
unit Of Measure
ng*hr/mL

Download exact source JSON → · Snapshot ctgov-results-25a395029948b04d52b1253f