NCT00033631 · OUTCOME
Prostate-specific Antigen (PSA) Failure by American Society for Therapeutic Radiology and Oncology (ASTRO) Definition
Results reported by the registry submitting party. Population, time horizon, units and missing values must be read together.
- Measure
- NUMBER
- Unit
- percentage of participants
- Interval / dispersion
- 95% Confidence Interval
- Time frame
- From randomization to date of failure (3 consecutive rises) or death or last follow-up. Analysis occurred after patients have been potentially followed for 5 years.
What was measured
Failure is defined as having 3 consecutive elevations of post-treatment PSA or starting hormones after one or more elevations in post-treatment PSA but before three consecutive elevations were documented. The failure day date was the midpoint between last non-rising PSA and first PSA rise. Failure rates are estimated by the cumulative incidence method. Patients last known to be alive are censored at date of last contact.
Analysis population: All eligible patients who did not withdraw consent
Groups in this outcome
70.2 Gy
70.2 Gy 3D-CRT/IMRT: Radiation will be delivered via 3D conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) in 1.8 Gy minimum dose fractions to a total of 70.2 Gy in 39 fractions. All fields treated once daily, five fractions per week. No more than 2% of the planning target volume and none of the clinical target volume may receive less than 70.2 Gy.
79.2 Gy
79.2 Gy 3D-CRT/IMRT: Radiation will be delivered via 3D conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) in 1.8 Gy minimum dose fractions to a total of 79.2 Gy in 44 fractions. All fields treated once daily, five fractions per week. No more than 2% of the planning target volume and none of the clinical target volume may receive less than 79.2 Gy.
| Group | Source count |
|---|---|
| 70.2 Gy | 751 |
| 79.2 Gy | 748 |
Reported measurements
Source class 1
| Group | Value | Spread | Lower | Upper | Comment |
|---|---|---|---|---|---|
| 70.2 Gy | 40.2 | Not reported | 36.6 | 43.7 | Not reported |
| 79.2 Gy | 25.2 | Not reported | 22.1 | 28.4 | Not reported |
Source statistical analyses
- ci Lower Limit
- 0.50
- ci Num Sides
- TWO_SIDED
- ci Pct Value
- 95
- ci Upper Limit
- 0.70
- group Ids
- OG000
- OG001
- non Inferiority Type
- SUPERIORITY_OR_OTHER_LEGACY
- p Value
- <0.0001
- p Value Comment
- Two-sided significance level = 0.05
- param Type
- Hazard Ratio (HR)
- param Value
- 0.59
- statistical Comment
- Reference arm is 70.2 Gy arm
- statistical Method
- Gray's test
Complete source fields
- analyses
- ci Lower Limit
- 0.50
- ci Num Sides
- TWO_SIDED
- ci Pct Value
- 95
- ci Upper Limit
- 0.70
- group Ids
- OG000
- OG001
- non Inferiority Type
- SUPERIORITY_OR_OTHER_LEGACY
- p Value
- <0.0001
- p Value Comment
- Two-sided significance level = 0.05
- param Type
- Hazard Ratio (HR)
- param Value
- 0.59
- statistical Comment
- Reference arm is 70.2 Gy arm
- statistical Method
- Gray's test
- classes
- categories
- measurements
- group Id
- OG000
- lower Limit
- 36.6
- upper Limit
- 43.7
- value
- 40.2
- group Id
- OG001
- lower Limit
- 22.1
- upper Limit
- 28.4
- value
- 25.2
- denoms
- counts
- group Id
- OG000
- value
- 751
- group Id
- OG001
- value
- 748
- units
- Participants
- description
- Failure is defined as having 3 consecutive elevations of post-treatment PSA or starting hormones after one or more elevations in post-treatment PSA but before three consecutive elevations were documented. The failure day date was the midpoint between last non-rising PSA and first PSA rise. Failure rates are estimated by the cumulative incidence method. Patients last known to be alive are censored at date of last contact.
- dispersion Type
- 95% Confidence Interval
- groups
- description
- 70.2 Gy 3D-CRT/IMRT: Radiation will be delivered via 3D conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) in 1.8 Gy minimum dose fractions to a total of 70.2 Gy in 39 fractions. All fields treated once daily, five fractions per week. No more than 2% of the planning target volume and none of the clinical target volume may receive less than 70.2 Gy.
- id
- OG000
- title
- 70.2 Gy
- description
- 79.2 Gy 3D-CRT/IMRT: Radiation will be delivered via 3D conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) in 1.8 Gy minimum dose fractions to a total of 79.2 Gy in 44 fractions. All fields treated once daily, five fractions per week. No more than 2% of the planning target volume and none of the clinical target volume may receive less than 79.2 Gy.
- id
- OG001
- title
- 79.2 Gy
- param Type
- NUMBER
- population Description
- All eligible patients who did not withdraw consent
- reporting Status
- POSTED
- time Frame
- From randomization to date of failure (3 consecutive rises) or death or last follow-up. Analysis occurred after patients have been potentially followed for 5 years.
- title
- Prostate-specific Antigen (PSA) Failure by American Society for Therapeutic Radiology and Oncology (ASTRO) Definition
- type
- SECONDARY
- unit Of Measure
- percentage of participants
Download exact source JSON → · Snapshot ctgov-results-191f4516d4760045304b24a0